UK to EU Shipping: We will dispatch all EU orders from Belgium. NO HASSLE, NO TAX, NO DUTY, NO EXTRA CHARGES UK to USA Delivery, No Hassle, Directly from the manufacturer. UK to Australia & New Zealand Shipping: We will dispatch all Orders from Australia. NO HASSLE, NO TAX, NO DUTY, NO EXTRA CHARGES UK to EU Shipping: We will dispatch all EU orders from Belgium. NO HASSLE, NO TAX, NO DUTY, NO EXTRA CHARGES UK to USA Delivery, No Hassle, Directly from the manufacturer. UK to Australia & New Zealand Shipping: We will dispatch all Orders from Australia. NO HASSLE, NO TAX, NO DUTY, NO EXTRA CHARGES
Categories
ATEN PE8108G 1U metered PDU angled view showing 8 outlets and LCD display
ATEN PE8108G 1U metered PDU angled view showing 8 outlets and LCD display
Front panel of ATEN PE8108G switched PDU with 10A outlets and RJ-45 port
Rear side of ATEN PE8108G PDU featuring IEC inlet and network connectors
ATEN PE8108G 1U metered PDU front and rear view with 8 outlets and network port
Logo

ATEN PE8108G, 1U 10A 8 Outlet Switched Metered PDU Free Eco Power Equipment

In Stock

New

UK Free Shipping UK Free Shipping over £249

$836.99 exc. VAT Note: VAT will be charged for UK & EU Countries at checkout. For Zero VAT (for EU buyers), please provide a VAT number at checkout.

Buy 5 or More Units - Unlock Priority Discounts!
Buy 20 or More Units - Get Exclusive Volume Discounts!


Also Support: Google & Apple Pay

Are you a reseller or placing a large order?
We're happy to offer Special Pricing tailored to your needs.
Click "Request Quote" or email us at [email protected] to get your best price today!

Add to Wishlist

Compare

Dispatch Time: Next Working Day Dispatch timelines are estimates and may vary due to unforeseen delays of 1-2 working days for small orders. Larger quantities may require additional processing time.

Product Code: PSEL-4731

MPN #: PE8108G

Product Condition: New

The ATEN PE8108G, 1U 10A 8 Outlet Switched Metered PDU Free Eco Power Equipment gives you eight outlets in one 1U unit and shows you the load at both the unit and outlet level, so you can plan your rack with confidence. Have you ever wondered how much power your rack is pulling, or worried that one overloaded outlet could knock out an entire setup? A metered PDU answers both worries.

Benefits of ATEN Metered PDUs

Nobody wants a late night trip to the server room just to restart a frozen device. You can switch any outlet on, off or power cycle it from your browser. Power-on sequencing brings each device up in the order you set, which takes the guesswork out of restarts. Even when an overload trips a breaker, the interface stays reachable so you can find the fault quickly. Safe shutdown support and upgradeable firmware help the unit stay useful for years.

Key Features of a 10A Metered PDU
  • Maximum input current per phase: 10 A. Plan your load so you stay under this limit.
  • Nominal input voltage: 100-240 V. It copes with a wide voltage range.
  • AC input frequency: 50 - 60 Hz. It suits both common mains frequencies.
  • AC outlets quantity: 8 AC outlet(s). Power eight devices from a single unit.
  • Ethernet LAN (RJ-45) ports: 1. One network port handles all remote control.
  • Rack capacity: 1U. It takes up only one rack unit.
  • Weight: 2.87 kg. It is light enough to handle during installation.
  • Height: 44 mm. A low profile suits crowded racks.
  • Depth: 432.4 mm. Check this against your cabinet before ordering.
  • Width: 219.3 mm. Use it to confirm clearance inside your cabinet.

Where a 10A Metered PDU Fits

Here are some everyday settings where this unit earns its place:

  • Small server rooms where you restart machines from your desk.
  • Home labs that need a fixed start-up order each time.
  • Network cabinets where you check the load before adding kit.
  • Remote sites where no one is on hand to reset a device.
  • Offices that want email alerts before a rack becomes overloaded.

Choosing the Right ATEN Metered PDU

Many buyers pick a basic power strip, then find out too late that they cannot see how much current each device draws. Others skip remote access and end up driving to the rack to reboot a frozen server. Some also forget about start-up order, so storage units power up after the servers that depend on them. These mistakes cost time and can cause more downtime than you expect.

This unit answers those doubts with facts you can check. Power status can be measured at the PDU or outlet level, and the eco Sensors Energy Management Software can automatically discover every PE device on your intranet and plot their readings in one place. Threshold alerts reach you through SMTP and Syslog, so you hear about a problem before it becomes an outage. The RTC also keeps the timer running during times of no power.


Specifications
Design
Product colourBlack
Housing materialMetal
MountingHorizontal
Rack capacity1U
PDU typesMonitored
Ports & interfaces
Ethernet LAN (RJ-45) ports1
AC outlet typesC13 coupler
Power plugC20 coupler
AC outlets quantity8 AC outlet(s)
Features
LED indicatorsLAN, Link, Power, Status
Management features
MonitoringCurrent
Power
Maximum input current per phase10 A
Nominal output voltage100-240 V
Maximum current10 A
AC input frequency50 - 60 Hz
Nominal input voltage100-240 V
Certificates
Compliance certificatesRoHS
Sustainability
Sustainability certificatesRoHS
Operational conditions
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 80%
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)0 - 50 °C
Weight & dimensions
Weight2.87 kg
Height44 mm
Depth432.4 mm
Width219.3 mm
Summary Details
LED indicatorsLAN