UK to EU Shipping: We will dispatch all EU orders from Belgium. NO HASSLE, NO TAX, NO DUTY, NO EXTRA CHARGES UK to USA Delivery, No Hassle, Directly from the manufacturer. UK to Australia & New Zealand Shipping: We will dispatch all Orders from Australia. NO HASSLE, NO TAX, NO DUTY, NO EXTRA CHARGES UK to EU Shipping: We will dispatch all EU orders from Belgium. NO HASSLE, NO TAX, NO DUTY, NO EXTRA CHARGES UK to USA Delivery, No Hassle, Directly from the manufacturer. UK to Australia & New Zealand Shipping: We will dispatch all Orders from Australia. NO HASSLE, NO TAX, NO DUTY, NO EXTRA CHARGES
Categories
Industrial Panel PCs

Industrial Panel PCs

17 Result(s) Found

Product Code: PNLP-134

Siemens SIMATIC IPC PX-39A Industrial Panel PC

Choosing among Industrial Panel PCs starts with one question: where will the unit run, and what must the operator do on it? A panel PC that suits a clean control room can fail on a factory floor with heat, vibration or dust. An undersized or slow unit frustrates operators and slows data logging. This guide covers the choices across the current PonDesk range so you can build a shortlist that fits your site, software and replacement schedule. Models in this range include Litemax IMRP-2435 and Moxa MPC-3150W-E2-T 15.6" Intel Atom x6211E 8GB RAM.

Industrial Panel PCs: Fanless Builds Versus Fan-Cooled Units

Cooling is the first split in the range. Fanless models have no moving cooling parts, so there is nothing to clog with dust or wear out. The listed DFI VP070-M8M, a 7-inch unit with an NXP i.MX 8M Quad Cortex A53 processor and 4GB/16GB memory, and the DFI VP101P-M8M-Q, a 10.1-inch unit with 4GB DDR4 and 16GB eMMC, are both described as fanless. For dusty cabinets, washdown areas or sites with rare maintenance windows, that is a practical advantage.

Fan-cooled units can run faster processors and sustain heavier loads, but their fans need clear air paths, filters and periodic cleaning. Check these three points in your cabinet:

  • Ambient temperature: measure the air around the mounting point, not the room. Heat from drives and power supplies adds to it.
  • Airflow: confirm whether the cabinet has vents, filters or its own fan, and where the intake and exhaust will sit.
  • Processor load: a unit showing a few screens and logging a few tags produces less heat than one running a full graphics-heavy HMI.

A hot cabinet favours a fanless design, which removes one failure point. Good airflow and demanding software may favour a fan-cooled unit. Check the operating temperature range in the datasheet before you shortlist.

Matching Screen Diagonal to Operator Distance and Task

Listed screen sizes run from 7 inches to 24 inches. The right size depends on how far the operator stands from the display and how much must be read at once. As a rule, the closer and more task-focused the operator, the smaller the screen can be. A supervisor reading a plant overview from several metres away needs a larger display with more on-screen detail.

Sizes in the range include:

  • 7-inch: the Moxa MPC-3070W-E4-T and DFI VP070-M8M, for single-machine controls and compact machine panels.
  • 10.1-inch to 12.1-inch: the DFI VP101-BT-454, DFI VP101P-M8M-Q, Moxa MPC-3120-E4-T and the 12.1-inch Intel Celeron J6412 unit, for operator stations with a few screens of process data.
  • 13.3-inch to 15.6-inch: the 13.3-inch Rockchip RK3568B2 unit, the 15-inch Intel Celeron J6412 unit, the R. STAH ORCA PM E54A, the Moxa MPC-3150W-E2-T and the Advantech PPC-415W-PD5A, which is listed as Full HD. Suited to multi-tag process views.
  • Control rooms, wall-mounted overviews and dense dashboards.

Resolution matters as much as diagonal. A large screen with low resolution can show less data than a smaller Full HD screen, so compare pixel counts on each listing.

Checking Touch Type on Each Capacitive Listing

Several listings name capacitive, 10-point touch: the 12.1-inch and 15-inch Intel Celeron J6412 units, the 13.3-inch Rockchip RK3568B2 unit, the 21.5-inch Industrial Embedded Panel PC with RK3588 CPU and the 21.5-inch Intel Celeron J6412 unit. The Moxa MPC-3150W-E2-T and Advantech PPC-421W are also listed as touch. Capacitive touch responds to light contact and supports multi-point gestures, which suits operators who work with gloves off and need pinch or swipe input.

On each listing, confirm:

  • That the touch type is stated as capacitive, not resistive or unspecified.
  • Whether multi-point input is stated, and how many points.
  • Whether the touch screen is glass-fronted, which affects cleaning and chemical resistance.
  • Whether the unit works with gloves or needs a bare finger. Ask the supplier if the listing is silent.

If a listing does not name a touch type, do not assume one. Get the supplier to confirm it in writing.

Choosing a Chip for Control Software, Viewing and Logging

The processor sets what the unit can run comfortably. The range covers several families:

  • Intel Atom: the DFI VP101-BT-454 (E3845, 4GB RAM), the Moxa MPC-3070W-E4-T and MPC-3120-E4-T (Elkhart Lake quad-core, the latter with 8GB DDR4) and the Moxa MPC-3150W-E2-T (x6211E, 8GB RAM). Well suited to a single HMI application with modest logging.
  • Intel Celeron J6412 (2.0 GHz): the 12.1-inch, 15-inch and 21.5-inch units. A common middle ground for HMI software, trending and data logging.
  • Intel Core: the Litemax IMRP-2435 (Core i3-1115G4E, 8GB/256GB), the Advantech PPC-415W-PD5A (Core i5) and the Advantech PPC-421W (Core i5, 13th Gen). Better for heavier graphics, many simultaneous screens or several services running at once.
  • A low-power option with a larger 18.5-inch display.
  • ARM-based: the NXP i.MX 8M Quad units from DFI, the 13.3-inch Rockchip RK3568B2 unit and the RK3588 21.5-inch unit. These suit fixed-function displays, but confirm that your HMI or logging software supports the operating system and drivers they ship with.

Start with the software vendor's minimum requirements, then add headroom for logging growth and future screens. Memory and storage often limit logging more than the processor does, so confirm those figures on each listing.

Hazardous-Area Models: Confirming the Rating Before You Buy

The R. STAH ORCA PM E54A is the hazardous-area model in this range. It is a 15-inch panel PC thin client listed with an IP66 rating and a hazardous-area designation. IP66 describes protection against dust and powerful water jets, which matters for washdown or outdoor sites. On its own, however, it does not show that a unit is approved for a specific hazardous area.

Before you shortlist it, get these points in writing from the supplier:

  • The exact hazardous-area classification and certificate for this model, and whether they cover the zone at your installation point.
  • Whether the certificate covers the configuration you intend to buy, including the thin-client setup.
  • Any installation conditions in the certificate, such as cable entries, ambient limits or service requirements.
  • Who on your side must sign off the installation under your site's safety procedures.

Do not rely on a product name or a single rating in a listing. Have your safety team review the certificate and site conditions before you order.

Replacing an Old HMI: Cutout, Depth and Lifecycle Checks

Replacing an existing HMI is often a fit problem, not a performance one. Measure the old cutout (the width and height of the opening in the panel) and the mounting depth behind it, allowing clearance for cables and connectors at the back. Then compare those figures with each datasheet. The product data in this range does not list cutout or depth figures, so take them from the manufacturer's drawings before ordering. Check the mounting method too: the panel PC must fix to the same surface, and any gasket must still seal the front.

Then plan the lifecycle. An HMI often outlives its software vendor's support window, and a replacement should run for years. Ask for:

  • The expected product lifecycle and the last-order date for the model.
  • How long spare parts and replacement units will be available.
  • The current datasheet, dimension drawings, and any applicable certificates or declarations.
  • Driver and operating system support for the processor, including the end date of that support.

Finally, run a parallel test. Install the new unit on a bench or spare cabinet, load your HMI project and log data through a full shift before changeover. That catches software and communication issues that no datasheet will show.

Industrial Panel PCs at PonDesk: What Buyers Can Expect

Buyers of industrial panel PCs need to know where a unit came from before it goes into a control cabinet. PonDesk is a UK-based platform, serving customers worldwide, that sources technology through trusted channels. Every product is selected and verified as genuine, so procurement teams can compare models on their specifications rather than questioning authenticity. Orders can be placed online, by phone or by email, and the team offers technical support through the buying process.

FAQ's

A fanless unit has no fan, so it has no moving cooling parts to clog with dust or wear out, while a fan-cooled unit moves air to shed heat. Fanless models include the DFI VP070-M8M, a 7-inch unit, and the DFI VP101P-M8M-Q, a 10.1-inch unit, both listed as fanless. Fanless suits dusty cabinets, washdown areas or sites with rare maintenance. Fan-cooled units can handle heavier processing, but their fans need clear air paths, filters and regular cleaning.

It depends on what the manufacturer states the rating covers, so check the datasheet for the rear housing, connectors and any gasket, not just the front bezel. No listed product here is named as IP65, so do not assume it. The R. STAH ORCA PM E54A is listed with IP66, which describes protection against dust and powerful water jets. Confirm exact coverage and test conditions with the supplier before relying on it for washdown.

It should cover the highest and lowest air temperature your cabinet will see, which the product data here does not state for any model. Measure the air at the mounting point, not the room, and add heat from drives and power supplies. Compare that reading with the operating range the manufacturer states in each datasheet. A hot cabinet needs a unit rated for that heat, and a fanless design removes one failure point.

Capacitive touch responds to light contact and supports multi-point gestures, while resistive touch needs pressure and usually handles one point at a time. Several listings name capacitive, 10-point touch, including the 15-inch Intel Celeron J6412 unit and the 21.5-inch Intel Celeron J6412 unit. Check that each listing states the touch type, and whether it works with gloves. If a listing does not name a touch type, ask the supplier to confirm it in writing.

Choose the smallest screen the operator can read at their working distance, with enough room for the data they must see at once. Listed sizes run from 7 inches to 24 inches. A single-machine control with a few values suits a 7-inch unit such as the DFI VP070-M8M or Moxa MPC-3070W-E4-T, while a supervisor overview needs a larger display. Also compare resolution, because a large low-resolution screen can show less than a smaller Full HD one.

An Intel Celeron J6412 unit is the usual middle ground for HMI, trending and logging, with Intel Core or ARM only where the software allows it. Intel Atom units such as the Moxa MPC-3150W-E2-T suit a single HMI application. Intel Core, as in the Advantech PPC-415W-PD5A, handles heavier graphics and several services at once. ARM-based units, such as the DFI VP070-M8M, suit fixed-function displays once your software is confirmed to run on their operating system.

Choose the mounting method by how the unit will be installed. A wall or arm mount suits a free-standing station, while a panel cutout suits a unit set into a cabinet door or machine front. Rack mounting suits a unit in a server or instrument rack. The product data here does not list VESA patterns, cutout sizes or mounting kits, so take those from the manufacturer's drawings and check the mounting surface and sealing gasket.

Choose a unit whose input range covers the supply voltage actually present in your control cabinet, rather than the nominal figure. The product data here does not give an input voltage range for any model, so take it from each manufacturer's datasheet. Check the polarity, the protection the supply needs upstream, and whether the power connector suits your wiring. If the listing is silent, ask the supplier to confirm the input range in writing before you order.

Match the port count to your devices: count the serial and Ethernet connections your PLCs, scanners and other devices need, then confirm the same counts and types on the datasheet of the unit you choose. The product data here gives no port counts for any model. Include a spare port for service laptops and future devices. Also check the port types, since a serial connection and an Ethernet connection are not interchangeable, and confirm any adapter or converter you need.

Only use a unit that holds a hazardous-area certificate covering your exact zone, and never assume it from a rating alone. The R. STAH ORCA PM E54A is the hazardous-area model in this range, listed with an IP66 rating. That listing alone does not prove approval for your site. Get the certificate, its classification, the configuration it covers and any installation conditions in writing, and have your safety team review them before ordering.

Not necessarily, but check the housing and front-surface material against your washdown and cleaning chemicals first. None of the products in this range is described with a stainless steel housing in the product data, so do not assume one. Check the datasheet for the enclosure material, the front-glass or touch-surface type and the sealing around the bezel. Ask the supplier to confirm the material and cleaning compatibility in writing.

Measure the old cutout width and height, plus the depth behind it. Then compare those figures with the manufacturer's dimension drawings for each candidate, because the product data here does not list cutout or depth figures. Check that the new unit fixes to the same surface and that any gasket still seals the front. Finish with a parallel test: load your HMI project and log data through a full shift.

The product data gives no lifetime figure, so judge each model by its lifecycle and support window. Ask the supplier for the expected product lifecycle, the last-order date and how long spare parts and replacement units will be available. Check the driver and operating system support for the processor, including its end date, because an HMI often outlives its software vendor's support window. Also request datasheets and drawings.

🍪 Cookies Notice

We use cookies to ensure you get the best experience. See our Privacy Policy.