UK to EU Shipping: We will dispatch all EU orders from Belgium. NO HASSLE, NO TAX, NO DUTY, NO EXTRA CHARGES UK to USA Delivery, No Hassle, Directly from the manufacturer. UK to Australia & New Zealand Shipping: We will dispatch all Orders from Australia. NO HASSLE, NO TAX, NO DUTY, NO EXTRA CHARGES UK to EU Shipping: We will dispatch all EU orders from Belgium. NO HASSLE, NO TAX, NO DUTY, NO EXTRA CHARGES UK to USA Delivery, No Hassle, Directly from the manufacturer. UK to Australia & New Zealand Shipping: We will dispatch all Orders from Australia. NO HASSLE, NO TAX, NO DUTY, NO EXTRA CHARGES

Categories

ComAp InteliDrive 700 Marine (ID3700MXBAA), Marine Engine Controller
ComAp InteliDrive 700 Marine (ID3700MXBAA), Marine Engine Controller

ComAp InteliDrive 700 Marine (ID3700MXBAA), Marine Engine Controller


Buy 5 or More Units - Unlock Priority Discounts!
Buy 20 or More Units - Get Exclusive Volume Discounts!


Also Support: Google & Apple Pay

Are you a reseller or placing a large order?
We're happy to offer Special Pricing tailored to your needs.
Click "Request Quote" or email us at [email protected] to get your best price today!

Add to Wishlist

Compare

Product Code: CNTR-236

MPN #: ID3700MXBAA

When a marine engine needs reliable control and monitoring in a vessel environment, the controller must handle varying DC supply conditions, engine signals, communication networks, and demanding onboard conditions. The ComAp InteliDrive 700 Marine is designed for this type of engine-control application, combining display, measurement, I/O, communication, and output control functions in one marine-oriented controller.

 
ComAp InteliDrive 700 Marine (ID3700MXBAA), Marine Engine Controller

 

The InteliDrive 700 Marine provides a central interface for monitoring and controlling marine engine systems. Its 24 V / 12 V DC supply capability and wide 8-36 V DC range allow it to operate across common marine power conditions, while the integrated power-supply and battery-sense measurements help monitor the controller's electrical supply.

The controller includes a 5" colour IPS TFT display with 800 × 480 px resolution, giving operators a local interface for viewing engine information and system conditions. Its front-side IP65 protection, marine-oriented environmental specifications, vibration and shock resistance make it suitable for installations where equipment can be exposed to movement, temperature changes, and other demanding conditions.

For engine and equipment signals, the controller provides multiple analog and binary inputs. The analog inputs can be configured for resistance, voltage, current, or thermocouple-related measurements, while the binary inputs support engine and system status signals with broken-wire detection. This allows different types of sensors and switching signals to be connected to the controller according to the monitoring requirements.

The InteliDrive 700 Marine also provides multiple outputs for controlling connected equipment. Its 12 binary outputs support high-side and other output functions, while analog outputs provide voltage, current, and PWM options. Additional PWM outputs can support applications requiring adjustable duty cycle and frequency control, making the controller suitable for engine control functions that require more than simple monitoring.

For integration with marine control systems, the controller includes Ethernet, USB, and isolated CAN communication interfaces, including CAN FD support. With its combination of engine I/O, local display, control outputs, communication interfaces, and marine-oriented operating conditions, it can be used as a central controller for marine engine monitoring and control systems.

 

The InteliDrive 700 Marine is a next-generation engine supervision controller for marine applications, designed to manage auxiliary, emergency, harbour, and propulsion engines on board vessels. Building on 25 years of ComAp marine engine control experience, it replaces the proven ID-DCU Marine platform with modern cybersecurity compliance, expanded connectivity, and support for all fuel types including methanol, LNG, and dual-fuel engines.
 

  • Advanced engine supervision for auxiliary, emergency, harbour, and propulsion marine applications
  • Cybersecurity compliance with IACS UR E27 and preparation for EU Cyber Resilience Act requirements
  • Multi-ECU communication supporting J1939 with switchable CAN baud rate (125/250/500 kbps)
  • Controller substitutability with Inteli RPU G2 providing independent shutdown capability for classified installations
  • Extensible for complex engine supervision systems via built-in embedded PLC interpreter
  • Interoperable with ComAp Power Management System via Ethernet/CAN and with third-party PMS
 
Key features
  • 24 V / 12 V DC nominal power supply with 8-36 V DC maximal range
  • 5" colour IPS TFT display with 800 × 480 px resolution
  • 12 analog inputs with switchable measurement functions
  • 12 binary inputs with broken-wire detection
  • 12 binary outputs with 0.5 A maximum current each
  • Ethernet 10/100 Mbit, USB Device Type-C and USB Host Type-A
  • Isolated CAN 1A, CAN 1B and CAN 2 communication with CAN FD
  • Front side IP65 protection with -30 °C to +70 °C operating temperature
 
Specifications
General  
Nominal power supply 24 V / 12 V DC
Maximal range 8-36 V DC
Power consumption (without modules) 7 W
RTC battery Replaceable, type CR1632 (3V)
Fusing power 10 A / 12x 0,5A BOUT
Max. Power Dissipation 7 W
Power supply measurement  
Power supply measurement range 0-40 V DC
Power supply measurement accuracy ±1% in range 8-36 V
Power supply Battery sense type Galvanically isolated (optoisolator)
Battery sense range 6.5-40 V DC
Battery sense accuracy ±1.5% in range 8-36 V
Environmental  
Operating temperature -30 °C to +70 °C (-40 ˚C to +70 ˚C)*
Storage temperature -40 ˚C to +80 ˚C
Operating humidity 95 % non-condensing
Vibration 5-25 Hz, ± 1.6 mm
  25-100 Hz, a = 4 g
EMC Immunity Spot frequencies at 10 V r.m.s.
  Radiated field 10 V/m
EMC Emission Radiated: 150-300 kHz @ 80-52dBμV/m
  0.30-30 MHz @ 52-34dBμV/m
  Conducted: 10-150 kHz @ 96-50dBμV
  150-350 kHz @ 60-50dBμV
  0.35-30 MHz @ 50dBμV
Protection degree Front side: IP65
  Back side: IP20
Shocks a = 500 m/s2
Surrounding air temperature rating 70 °C.
Suitable for pollution degree 2. Overvoltage Category III.
Output / Charging  
Max. output current 250 mA
Charging fail threshold Adjustable
Display  
Type Build-in colour IPS TFT 5"
Resolution 800 × 480 px
Brightness backlight 600 cd/m2 (60°C), 70% (70°C)
Communications  
USB Device Non-isolated Type-C connector
USB Host Non-isolated Type-A connector
Ethernet 10/100 Mbit
CAN 1A 125 / 250 / 500 kbps, isolated
CAN 1B 125 / 250 / 500 kbps, isolated
Terminator impedance 120 Ω
CAN 2 250 / 50 kbps, isolated
Terminator impedance 120 Ω
Analog inputs  
Group 1 AI1 – AI4  
Number 4, switchable (R/U/I)
Range R = 0-15 kΩ; U = 0-10 V; I = 0-20 mA
Input impedance U: > 100 kΩ
  I: 170 Ω
Accuracy R: ±(5 Ω + 2 % of reading) for 0-250 Ω
  R: ±4% of reading for 250-5000 Ω
  R: ±6% of reading for 5k-10k Ω
  R: ±10% of reading for 10k-15k Ω
  U: ±(100 mV + 1 % of reading)
  I: ±(0.2 mA + 1 % of reading)
Group 2 AI5 – AI8  
Number 4, switchable (U/R)
Range R = 0-15 kΩ (3W); U = TC J,K,L (0-60 mV)
Input impedance U: > 85 kΩ
Accuracy R: ±(2 Ω + 0.5 % of reading) for 0-2500 Ω
  R: ±2 % of reading for 2.5k-15k Ω
  U: ±(1 mV + 0.5 % of reading) for 0-60 mV
+5 V Power supply output  
Typical max. current 100 mA
Output current limiter 141 mA ±5.1%
Frequency input  
Voltage input range 4 V to 50 Vpk-pk in range 4 Hz to 1 kHz
  6 V to 50 Vpk-pk in range 1 kHz to 5 kHz
  10 V to 50 Vpk-pk in range 4 Hz to 10 kHz
Frequency input range 4 Hz to 10 kHz
Frequency measurement tolerance 0.2 % from range 10 kHz
Binary inputs  
Group 1 BIN1 - BIN4  
Number 12, non-isolated (BIN1-4 individually adjustable EoL, BIN5-12 group adjustable EoL)
Close/Open indication 0-2 V DC close contact
  6-36 V DC open contact
Input impedance 4.7 kΩ
Input range 0 - 36 V DC
Minimal input signal duration 110 ms
Broken Wire detection individually adjustable EoL; open curcuit, short to +/-
BW impedance range 200-2500 Ω
Group 2 BIN5 - BIN12  
Number 8, non-isolated, type group adjustable
Close/Open indication 0-2 V DC close contact
  6-36 V DC open contact
Input impedance 4.7 kΩ
Input range 0 - 36 V DC
Minimal input signal duration 110 ms
Broken Wire detection fixed EoL; open circuit
BW impedance 220 Ω
EoL Parallel Resistor 10 kΩ
Binary Outputs  
Number 12 (BO1-8 high-side + BO9-12)
Max. current 0.5 A each
Open Load detection open load, short to +/-
Switching to positive supply terminal  
Nominal conditions 50% load on all outputs = 3 A
  1.5 A (entire group) above 60°C
Isolation Non-isolated
Analog output 1  
Output Type ±10 VDC
Output Accuracy 1% from set value ± 100mV
Output Maximum Load 5 mA
Output Type 0V / 5V @ 500 Hz PWM
Output Accuracy ±1% from range 5V
Output Maximum Load 20 mA
Analog output 2  
Isolation Isolated
Type max ± 10 V DC
Output Accuracy 1% from set value ± 100mV
Output Maximum Load 5 mA
Current Output Type ±20 mA
Current Output Accuracy 1% from set value ± 200uA
Current Output Maximum Load 500 Ω
Output Type 0V / 5V @ 500 Hz PWM
Output Accuracy ±1% from range 5V
Output Maximum Load 20 mA
Analog output 3-4  
Output voltage Power input voltage
Output nominal frequency (range) 1000 Hz (100 - 3000Hz)
Maximum output current (requires auxiliary power supply) 3A each (60°C)
  2A each (70°C)
Control type Duty cycle; adjustable dithering
Output voltage accuracy ±0.5% from range 10V
Output frequency accuracy ±1% from set value
Output duty cycle accuracy ±0.5% from absolute value
PWM Power measurement accuracy 2% from absolute value
Load Voltage Feedback measurement accuracy 2% from absolute value
Dimensions & Weight  
dimensions  
Height 157 mm
Width 227 mm
Depth 48 mm
weight  
ontroller 690 g
Package 795 g

 

Downloads

Customer Reviews

Be the first to write a review

You can upload up to 3 images (JPG or PNG formats only).
Please fill the reCAPTCHA.
Please fill the reCAPTCHA.